{"id":55287,"date":"2026-11-23T16:36:57","date_gmt":"2026-11-23T20:36:57","guid":{"rendered":"https:\/\/www.groupesidex.com\/cedar-shingle-installation-guide\/"},"modified":"2026-11-23T16:36:57","modified_gmt":"2026-11-23T20:36:57","slug":"cedar-shingle-installation-guide","status":"publish","type":"post","link":"https:\/\/www.groupesidex.com\/en\/cedar-shingle-installation-guide\/","title":{"rendered":"SIDEX cedar shingle installation guide"},"content":{"rendered":"<p class=\"lead\">How to install SIDEX cedar shingles, as set out in the SIDEX <em>Installation Guide | Cedar Shingles<\/em> (version 2019-12-01). The complete guide is still available as a PDF.<\/p>\n<aside class=\"sx-note\">\n<p><strong>Installation Guide | Cedar Shingles<\/strong> \u00b7 PDF, 3 pages, version 2019-12-01<\/p>\n<p><a class=\"sx-btn\" href=\"\/wp-content\/uploads\/installation-guide-cedar-shingles-sidex.pdf\" download>Download the guide (PDF, 1.9 MB)<\/a><\/p>\n<\/aside>\n<p>Product: SIDEX <a href=\"\/en\/shingle\/\">cedar shingles<\/a>.<\/p>\n<div class=\"sx-note\">\n<p>Before proceeding with the installation, please read the following pages to understand the steps and requirements. Failure to follow any step may result in the voiding of your warranty.<\/p>\n<\/div>\n<div class=\"sx-howto\" data-howto-name=\"Install SIDEX cedar shingles\">\n<div class=\"sx-step\" id=\"storage\">\n<h2>1. Storage<\/h2>\n<p>Storage is just as important as installation. If you cannot install the shingles immediately, store it in a cool, dry place.<\/p>\n<p>At the end of each day, the uninstalled cedar shingles should be covered.<\/p>\n<\/div>\n<div class=\"sx-step\" id=\"nails-and-staples\">\n<h2>2. Choose the nails and staples<\/h2>\n<p>Two types of fasteners can be used:<\/p>\n<ul>\n<li>Stainless steel nail with a minimum 7\/32\u2033 wide head.<\/li>\n<li>Stainless steel staples with minimum 7\/16\u2033 crown and minimum 16 gauge.<\/li>\n<\/ul>\n<p>There should always be two fasteners per shingle.<\/p>\n<ul>\n<li>Attach fasteners 3\/4\u2033 from each side edge and 1\u2033 above the bottom of the next top course.<\/li>\n<li>Fasteners must penetrate at least 1\/2\u2033 into a rigid nailing base under the shingle but must not be under or over driven.<\/li>\n<\/ul>\n<figure><a href=\"\/wp-content\/uploads\/sidex-guide-bardeau-fixation.png\"><img src=\"\/wp-content\/uploads\/sidex-guide-bardeau-fixation.png\" width=\"580\" height=\"450\" alt=\"A correctly driven shingle fastener, then two incorrect ones, under-driven and over-driven.\" loading=\"lazy\" decoding=\"async\"><\/a><figcaption>Left, a correctly driven fastener; right, two incorrect fasteners, under-driven and over-driven. Source: SIDEX Installation Guide | Cedar Shingles.<\/figcaption><\/figure>\n<\/div>\n<div class=\"sx-step\" id=\"starting-row\">\n<h2>3. Install the starting row<\/h2>\n<p>Before starting the installation, make sure to choose a method to ensure an air gap under the singles :<\/p>\n<ul>\n<li>The most common is the ventilation membrane designed for cedar shingles installed over the building\u2019s air barrier. The shingles are then fastened through to the rigid nailing base.<\/li>\n<li>The second method is to install horizontal furring strips (1\u2033x3\u2033) over the air barrier at the air barrier at a spacing corresponding to the desired pitch (4\u2033 to 6\u2033) in order to form the nailing bed.<\/li>\n<\/ul>\n<p>The starting row is composed of 2 layers of full-length shingles and overlapping the bottom joints by at least 1 1\/2\u2033. In addition to waterproofing, this will ensure that the membrane or furring is not visible under the shingles.<\/p>\n<\/div>\n<div class=\"sx-step\" id=\"cuts-and-touch-ups\">\n<h2>4. Cut and touch up<\/h2>\n<p>Since cedar is a soft wood, you can simply make a straight cut on the surface of the shingle and then bend it along the cut line to make a neat break.<\/p>\n<p>Always repaint the ends after a cut, even if they are not visible once installed. Use a small paintbrush to avoid drips and spills.<\/p>\n<\/div>\n<div class=\"sx-step\" id=\"exposure\">\n<h2>5. Respect the exposure<\/h2>\n<ul>\n<li>For walls, we strongly recommend a 5\u2033 (22 square feet per box) or 5 1\/2\u2033 (25 square feet per box) exposure (footprint).<\/li>\n<li>The spacing between shingles must be at least 1\/8\u2033.<\/li>\n<li>Do not glue the shingles together and leave an offset of 1 1\/2\u2033 between the joints.<\/li>\n<li>If possible, leave at least 4\u2033 of eaves over and under the windows. The last course at the top of the wall should have no less than 4\u2033 of eaves.<\/li>\n<li>No joint should be on a node.<\/li>\n<li>Over door and window headers, drip edges, stone sills, metal flashing metal flashing, it is important that the shingles be 1\/4\u2033 to 1\/2\u2033 shorter, in order to leave a space for water drainage and air circulation.<\/li>\n<\/ul>\n<\/div>\n<div class=\"sx-step\" id=\"corner-finishing\">\n<h2>6. Finish the corners<\/h2>\n<p>The <strong>first option<\/strong> is to install corners and edges around your openings and building corners before the shingles are installed.<\/p>\n<p>The <strong>second<\/strong> is to overlap the shingles so that the joints alternate successively on either side of the corner. Secure the bottom corner of the shingle with a stainless-steel finishing nail.<\/p>\n<figure><a href=\"\/wp-content\/uploads\/sidex-guide-bardeau-coin-en.png\"><img src=\"\/wp-content\/uploads\/sidex-guide-bardeau-coin-en.png\" width=\"958\" height=\"748\" alt=\"Woven shingle corner: right and left joints alternating, 3 in minimum width, finishing nail.\" loading=\"lazy\" decoding=\"async\"><\/a><figcaption>Woven corner: right and left joints alternating, 3\u2033 minimum width, finishing nail penetrating the side shingle. Source: SIDEX Installation Guide | Cedar Shingles.<\/figcaption><\/figure>\n<p><strong>*Cutting at 45\u00b0 to round the corners will void your warranty.<\/strong><\/p>\n<p>*Don\u2019t forget to touch up the cuts with the stain provided.<\/p>\n<\/div>\n<\/div>\n<h2>After installation: maintenance<\/h2>\n<p>For cleaning, touch-ups and how often to restain, see the SIDEX <a href=\"https:\/\/www.groupesidex.com\/en\/wood-siding-maintenance-guide\/\">wood siding maintenance guide<\/a>.<\/p>\n<nav class=\"sx-related\" aria-label=\"Related guides and pages\">\n<h2>Read next<\/h2>\n<ul>\n<li><a href=\"\/en\/shingle\/\">SIDEX cedar shingles<\/a><\/li>\n<li><a href=\"https:\/\/www.groupesidex.com\/en\/wood-siding-maintenance-guide\/\">Wood siding maintenance guide<\/a><\/li>\n<li><a href=\"https:\/\/www.groupesidex.com\/en\/horizontal-wood-siding-installation-guide\/\">Installation guide: horizontal wood siding<\/a><\/li>\n<li><a href=\"https:\/\/www.groupesidex.com\/en\/documents\/\">All SIDEX technical documents<\/a><\/li>\n<\/ul>\n<\/nav>\n<div class=\"sx-cta\">\n<div>\n<h2 class=\"ignore\">A question about installation?<\/h2>\n<p>SIDEX customer service: <a href=\"tel:+18198436286\">819-843-6286<\/a>.<\/p>\n<\/div>\n<p><a class=\"sx-btn\" href=\"https:\/\/www.groupesidex.com\/en\/contact\/\">Contact us<\/a>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Two stainless steel fasteners per shingle, 3\/4\u2033 from the side edges and 1\u2033 above the next course; 5\u2033 or 5 1\/2\u2033 exposure on walls; at least 1\/8\u2033 between shingles and a 1 1\/2\u2033 offset between joints. Cutting corners at 45\u00b0 voids the warranty.<\/p>\n","protected":false},"author":1,"featured_media":54426,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_tactik_schema_jsonld":"","_tactik_schema_enabled":true,"footnotes":""},"categories":[280],"tags":[],"class_list":["post-55287","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-maintenance-durability"],"acf":[],"tactik_schema_status":{"template":"","enabled":true,"has_schema":false,"valid":false,"types":[],"lint":[]},"_links":{"self":[{"href":"https:\/\/www.groupesidex.com\/en\/wp-json\/wp\/v2\/posts\/55287","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.groupesidex.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.groupesidex.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.groupesidex.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.groupesidex.com\/en\/wp-json\/wp\/v2\/comments?post=55287"}],"version-history":[{"count":0,"href":"https:\/\/www.groupesidex.com\/en\/wp-json\/wp\/v2\/posts\/55287\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.groupesidex.com\/en\/wp-json\/wp\/v2\/media\/54426"}],"wp:attachment":[{"href":"https:\/\/www.groupesidex.com\/en\/wp-json\/wp\/v2\/media?parent=55287"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.groupesidex.com\/en\/wp-json\/wp\/v2\/categories?post=55287"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.groupesidex.com\/en\/wp-json\/wp\/v2\/tags?post=55287"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}